Circutor CVM-NET Series Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 2
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
CVM-NET
M98229901-03-14A
FOUR CVM-NET QUADRANTS
90º
180º
-90º
Capacitivo
Capacitivo
Inductivo
Inductivo
2.7.- CVM-NET COMMUNICATIONS
One or several CVM-NET analyzers can be connected to a computer or PLC. This system
makes it possible to centralise the data in a single record point, in addition to the normal
operation of each of them (PowerStudio® System). The CVM-NET has an RS-485 serial
communication output. If more than one analyzer is connected to a serial communication bus
(RS-485), each analyzer must be assigned a peripheral number or address (from 01 to 255),
with a maximum of 32 units per communication bus, so that the central computer sends the
queries from the various records measured or calculated to these addresses.
The CVM-NET power analyzer communicates using the MODBUS RTU© protocol (Pulling
Question / Answer).
3.- TECHNICAL SPECIFICATIONS
Power circuit:
- Single-phase:
- Voltage tolerance:
- Frequency:
- Maximum consumption:
- Working temperature:
- Humidity (non-condensing):
AC version
230 V AC
-15% / +10%
50 - 60 Hz
3.0 V·A
-10 …..+ 50 ºC
5 ….. 95%
DC version
20…120V DC
1,2…2 W
-10 …..+ 50 ºC
5 ….. 95%
Plus version: C. & DC
85..265V AC /95..300V DC
50 - 60 Hz (AC mode.)
3.0 V·A/ 3W
-10 …..+ 50 ºC
5 ….. 95%
Metering circuit:
- Nominal voltage: phase-neutral / between phases
- Frequency:
- Nominal current:
- Permanent overload:
- Voltage consumption of the circuit:
- Current consumption of the circuit: ITF / Shunt
300 V AC / 520 V AC
45 ~ 65 Hz
I
n
/ 5 A
1.2 I
n
0.7 V·A
0.9 V·A / 0.75 V·A
Mechanical characteristics:
- Case material:
- Protection titted unit (frontal):
- Protection non-fitted unit (sides and rear cover):
- Dimensions (mm):
- Weight:
V0 self-extinguishing plastic
IP 51
IP 31
85 x 52 x 70 mm (3 modules)
0.210 kg
Features of the output transistors
- Type: Opto-isolated transistor (commutator open).
- Maximum switching voltage:
- Maximum switching current:
- Maximum frequency:
- Pulse duration:
NPN
24 V DC
50 mA
5 pulse / s
100 ms
Precisions Class:
- Voltage:
- Current:
- Power / Energy:
Measurement sensors: Current / Voltage
Power factor:
Full-scale measurement margin: ITF / Shunt
Temperature sensor: Precision / Working window
- Temperature measurement: with forced ventilation
- Temperature measurement: without forced ventilation
Maximum altitude operating:
0.5% ± 1 digit
0.5% ± 1 digit
1% ± 1 digit
External transformers / direct voltage
0.5 to 1
0.2 ..... 120% / 2 ..... 120%
± 2 ºC / -10 ….. +50 ºC
+ 14.0 ºC
+ 3.5 ºC
2000 meters
Safety:
Category III - 300 V AC / 520 V AC EN-61010 Class II double-insulated electric shock
protection.
The system should be connected to a power supply circuit protected by fuses gl or M type,
with current ratings between 0.5 and 1 A. It should be provided with a MCCB or equivalent
device to switch off the system from the power supply circuit. The power supply and
voltage measuring circuit is connected with cable minimum cross section of 1 mm2
Standards:
IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN 61000-6-3,
EN 61000-6-1, EN 61010-1, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 55011, CE
4.- CONNECTIONS
4 wires / 3 wires ( low voltage )
3 wires (2 voltage and 3 current transformers)
3 wires (2 voltage and 2 current transformers)
S2
P2
S1
P1
L1
L2
L3
N
S2
P2
S1
P1
S2
P2
S1
P1
N
V
L1
V
L2
V
L3
min
max Pd
max
clear
CO MM
CPU
CVM-MINI
reset reset energy
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15
Alimentación
Power Supply
S2
P2
S1
P1
L1
L2
L3
S2
P2
S1
P1
S2
P2
S1
P1
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15
b
B
a
A
b
B
a
A
V
L1
V
L2
V
L3
Alimentación
Power Supply
L1
L2
L3
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15
b
B
a
A
b
B
a
A
V
L1
V
L2
V
L3
S2
P2
S1
P1
S2
P2
S1
P1
Alimentación
Power Supply
5.- TECHNICAL SERVICE
In the event of any equipment failure or any operational queries please contact the technical service of CIRCUTOR S.A.
CIRCUTOR S.A. - After sales service
Vial Sant Jordi, s/n
08232 -Viladecavalls (Barcelona)
tel - (+34) 93 745 29 00 & fax - (+34) 93 745 29 14
E-mail :
[email protected] www.circutor.com
Vista de página 1
1 2

Comentários a estes Manuais

Sem comentários