Circutor DISPENSER Series Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 124
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
In normal mode, the price of energy remains unmodied and users pay for energy at the price
stipulated.
Table 2 shows the values that these factors can adopt.
Table 2: Range of values of the energy price factor
Energy factors Range of values
Bonus factor 0.4...1
Restriction factor 1.2...3
3.3.- CONTROLLING THE MAXIMUM POWER
One of the functions of the Dispenser is to control the limits of the power that can be consumed
by the user.
The unit limits the maximum power available according to the type of contract and status of the
micro-grid. If this power level is exceeded, the general relay is opened, disconnecting the power
supply from the subscriber. ( 5.2.4.1.- GENERAL RELAY)
This function allows each user of the installation to dene the maximum power available, estab-
lishing the number of loads that can be connected to the grid. Therefore, this limiter can be used
to ensure that the power for which the electrical network has been designed is never exceeded.
The Contracted power is dened in the DISPENSER-SOFT application as:
Contracted power = Base power x Power multiplier
Where: Base power : base power of the micro-grid.
Power multiplier : multiplier factor that depends on the type of contract.
The maximum power value is modied according to the status of the micro-grid.
3�3�1�- NORMAL MODE
In this operating mode, the maximum power that can be consumed by the user is equal to the
contracted power.
Figure 7: Controlling the maximum power, Normal mode�
13
Instruction Manual
Dispenser Universal System
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 123 124

Comentários a estes Manuais

Sem comentários