INSTRUCTION MANUAL(M059B01-03-15A)Low voltage capacitor bank with static operation.OPTIM HYB Series

Página 2

 The available combinations for standard models are selected through internal mini-dips. The programming is done in-factory and should not be modied

Página 3

Any modication to the regulator connections must be performed exclusively by CIRCUTOR personnel or by those properly trained in its useThe regulator&

Página 4 - CONTENTS

Figure 5: LEDs on the Computer HYB Hybrid Regulator.Table 3:LEDs on the Computer HYB Hybrid Regulator.LED DescriptionL1/1 ...L1/8Indicates the activat

Página 5 - REVISION LOG

2.1.2. CPC2 PANEL: ZERO SWITCHING CONNECTION CONTROL BY TWO SIN-GLE-PHASE STAGESThe static capacitor banks come equipped with CPC2 panels in the singl

Página 6 - Figure 1)

2.1.3. SINGLE-PHASE POWER BLOCKThe single-phase power block of a OPTIM HYB unit consists of 6 to 9 groups of thyristor-diode semiconductors + single-p

Página 7 - Figure 2)

3.- INSTALLATION 3.1.- PRELIMINARY RECOMMENDATIONSIn order to use the unit safely, it is critical that individuals who handle it follow the saf

Página 8 - Figure 4.:

Do not touch the terminals or active parts of the unit until you have veried that voltage is not present. If you have to handle or touch the terminal

Página 9

3.3.- INSTALLATION LOCATIONIt is important to maintain a minimum distance around the unit to facilitate cooling. In self-supporting cabinets, t

Página 10

Figure 8: Cable entry point on the OPTIM HYB 2 model. 3.5.-POWER CIRCUITConnect input terminals L1, L2, L3 and N (power circuit) to the mains u

Página 11 - OPTIM HYB Series

3.6.- EXTERNAL ISOLATION AND PROTECTION ELEMENTSThe capacitor bank has a manual internal quadrupole isolator, but it must be connected to a lin

Página 12 - LED Description

2OPTIM HYB Series Instruction Manual

Página 13 - Alimentación Potencia

3.9.- CURRENT TRANSFORMER (CT) CONNECTION For standard units that come with a CVM-MINI-RS485 power analyzer: You must place 3 current transform

Página 14

Figure 12: Current transformer (CT) connection terminals.Once the cables are installed, disconnect the jumper connecting the 3 S1 and S2 terminals of

Página 15

4.- START-UP OF A HYBRID CAPACITOR BANK 4.1.- BEFORE START-UPHybrid capacitor banks come with a computer HYB-type power factor regulator and st

Página 16 - 6.- TECHNICAL FEATURES”)

Figure 14: Quadrupole circuit breaker for the auxiliary power circuit.5.- Connect the power supply of the OPTIM HYB capacitor bank, closing the genera

Página 17

value of the ashing digit.When the on-screen value is that desired, press the min key to go to the next digit to modify the other values.If you press

Página 18

L1L2L3NRED CARGA3x400 V / 1x230 V - 50 Hz L1L2L3S1NTB1BATERÍA DECONDENSADORES1S1 1S2S1 S2S1 S2S1 S2T.I.1T.I.2T.I.32S1 2S2 3S1 3S2Figure 17: Connection

Página 19

4.3.- CHECKS ONCE THE CAPACITOR BANK HAS BEEN CONNECTED TO THE 1.- After start-up, make sure that the unit is operating correctly. An indicatio

Página 20 - Figure 11 and Figure 12)

5.- MAINTENANCE 5.1.- SAFETY REGULATIONSTake the safety regulations listed in section of this manual into account before operating the units “3

Página 21 - Figure 13)

5.2.2. TIGHTENING TORQUE OF THE ELECTRICAL CONNECTIONSThe connections must be tight.The torques of the circuit breakers are indicated in Table 4 and T

Página 22 - Figure 14)

5.2.4. KEY POINTS FOR INSPECTING STATIC SWITCHES Check that the plastic parts are not blackened and do not show signs of burning or hardening. Check

Página 23

SAFETY PRECAUTIONS DISCLAIMERCIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-tions set out in this instruct

Página 24

5.3.- MAINTENANCE WITH THE CAPACITOR BANK CONNECTED Check that the main switch turns on and off without having to force the mechanism. If

Página 25 - CONDENSADORES

6.- TECHNICAL FEATURESElectrical featuresUsage voltage and nominal frequency Un / fn, listed on the labelDesign voltage Un + 10% Nominal power and di

Página 26 - Table 8) and nev

7.- OPTIM HYP TYPE DIAGRAMDENOMINACIONFECHAUNIDAD DIMESCALAAPROBADODIBUJADONOMBRESUSTITUIDO PORSUSTITUYE ACODIGOEQUIPO/S13/10/201413/10/2014L1L2L3C1

Página 27

DENOMINACIONFECHAUNIDAD DIMESCALAAPROBADODIBUJADONOMBRESUSTITUIDO PORSUSTITUYE ACODIGOEQUIPO/S13/10/201413/10/2014K1L1L2L3N50 Hz 440 V3NHYB1-XXX-440CO

Página 28

8.- MAINTENANCE AND TECHNICAL SERVICE 9.- GUARANTEE• No returns will be accepted and no unit will be repaired or replaced if it is not ac-companied b

Página 29

10.- CE CERTIFICATE35Instruction ManualOPTIM HYB Series

Página 30

CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor

Página 31 - 6.- TECHNICAL FEATURES

CONTENTSSAFETY PRECAUTIONS ...

Página 32 - Icu=10kA/400VCA

REVISION LOGTable 1: Revision log.Date Revision Description11/14 M059B01-03-14A Initial Version02/15 M059B01-03-15AChanges in the following sections:

Página 33

1.- VERIFICATION UPON RECEPTION 1.1.- RECEPTION PROTOCOLCheck the following points when you receive the unit: a) The unit meets the specicati

Página 34

When unloading and moving the unit, use a forklift with forks long enough to support the entire length of the base. Otherwise, the forks should be lon

Página 35 - 10.- CE CERTIFICATE

2.- PRODUCT DESCRIPTIONThe purpose of this manual is to assist during the installation, start-up and maintenance of OPTIM HYB series lo

Página 36 - Vial Sant Jordi, s/n

The communication parameters installed in the unit are: Speed: 9600 bps, parity: No, data bits: 8, stop bits : 1The standard OPTIM HYB models come