Circutor CIRLAMP Series Manual do Utilizador Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 102
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 66
Container element: <IntervalMemory>
< IntervalMemory> is the container element for information relating to the memory work inter-
val:
Table 74:File L03, element <IntervalMemory>
Attribute Description
time1 Duration in minutes of memory work interval number one.
power1
% of power in the memory work interval number one.
time2
Duration in minutes of memory work interval number two.
power2
% of power in memory work interval number two.
time3
Duration in minutes of memory work interval number three.
power3
% of power in memory work interval number three.
time4
Duration in minutes of memory work interval number four.
power4
% of power in memory work interval number four.
Container element: <TemporalInterval>
<TemporalInterval> is the container element for information relating to the work time interval:
Table 75:File L03, element <TemporalInterval>
Attribute Description
time Duration in minutes for the work time interval.
power
% of power in the work time interval.
Container element: <Measurement>
<Measurement> is the container element for information relating to the unit measurements:
File L03, element <Measurement>
Attribute Description
Voltage Voltage
Current
Current
activePower
Active power.
reactivePower
Reactive power.
apparentPower
Apparent power.
powerFactor
Power factor
Container element: <Alarms>
<Alarms> is the container element for information relating to alarm adjustment:
File L03, element <Alarms>
Attribute Description
broken Blown alarm status.
blink
Intermittent alarm status.
capacitor
Open capacitor alarm status.
67
Instruction Manual
CirLAMP system
Vista de página 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 101 102

Comentários a estes Manuais