INTERRUPTORDIFERENCIAL DERECONEXIÓN AUTOMÁTICA
SEL-RECLOSINGRCCB
DESCRIPCIÓNGENERAL
DESCRIPCIÓNLED´s Y MODOREARME.
-InterruptorDiferencialclase A (IEC1008.1)
-DisponedesistemadeREARME AUTOMÁTICO.
·ModoControl Aislamiento.
·ModoSecuencia Tiempo.
-MontajeenCarrilDIN46277(EN50022)
-Ledverde.
·OFF,REConexiónMANUAL
·ON,REConexión AUTOMÁTICA
-conpárpadeorápido,indicauncambioenel
mododereconexión.
-Ledrojo.
·OFF,Interruptordiferencialnodisparado.
·ON,Interruptordiferencialdisparado.
-conpárpadeolento,temporizalasecuencia
dereconexión.
-conparpadeorápido,realizatestdeaislamiento.
-fijo,agotadalastemporizacionesysecuencias,
quedabloqueado.
-Modorearme.
·Mediantecontroldeaislamiento,conmutadorarribaM
·Mediantesecuenciadetiempos,conmutadorabajo T
-
MODODEFUNCIONAMIENTO.
MODODE ONEXIÓN
AUTOMÁTICA.FUNCIONAMIENTO
-ParahabilitarlaREConexionautomática,lataparojatransparentetienequecerrarse
deslizandosesuavementesobreelinterruptordiferencial.Elequipoestaenmodo AUTO,led
verdeestaenON(parpadeandoencasodeestarenmododeaislamiento)yportantodespués
deunadesconexiónpordisparodiferencialelequipoempiezalareconexionautomática.
-Paradeshabilitarestafuncion,lataparojatransparentedebeestarabierta.Elequipoestaen
modoMANUAL,ledverdeestaenOFFyportantonoreconectaautomaticamente.
-
TensionNominal.....................230/400Vac50-60Hz
IntensidadNominal.....................40 A c.a./63 A c.a.
Sensibilidad,I n........................30mA
Resistenciaaondasdechoque.....250 A 8/20 s/200 A 0,5 s
Resistenciaalcortocircuito..............6.000 A segunVDE0664
IntensidadNominaldeaperturaycierre.......................500 A
Clase............................................................................ A (IEC1008.1)
Numerodepolos..........................................................2/4
Tensióndetest............................................................2polos,entre140y230Vac
4polos,entre190y400Vac
Bornesdeconexion....................................................35mm2
Gradodeproteccion....................................................IP40(DIN40050)
Temperaturadestock...................................................-55Ca55C
Temperaturaservicio.....................................................-25Ca55C
Normativa......................................................................IEC61008.1
Cajacolor......................................................................RAL 7035
- (mm)
REC
CARACTERISTICASINTERRUPTORDIFERENCIAL
DIMENSIONES
D
m
m
Conelinterruptordemodoreconexión
elequipoestaenmododeSecuencia .
Despuesdeunadesconexiónpordisparopordiferencialseintentarealizarhastaunmáximode
6reconexionesconunatemporizaciónentrerearmesde10,20,30,60,120y600segundos.En
estasituaciónelledrojoparpadealentamenteindicandotemporizaciónentrereconexiones.
Llegandoalanoreconexionpermanentesiseagotaelnumeroderearmesyelproblema
persiste.EntalcasoelledrojoquedaenONfijamente.Eltiempoderesetdelnumerode
reconexionesesde300segundos.
-Conelinterruptorhacia
seestaenmodo ,elequiporealizalamisma
operacióndetemporizaciónderearmessoloqueantesdereconectarrealizauntestdecontrol
deaislamiento,5segundosdesupervisióncontinua,duranteelcualelledrojoparpadea
rápidamente.Sieltestesnegativoelequiporeconectaautomaticamente.Sieltestespositivo,
elequiponoreconectaytemporizaelsiguientetiempo.Unavezagotadalasecuenciaelequipo
sebloquea,enestadodenoreconexiónpermanente,quedandoelledrojofijamenteenON.
abajo T
iempo
arriba supervisióndefuga
Código
code
Descripción
Description
Polos
Poles
IntensidadNominal(A)
NominalCurrent
P2661
1REC2C2P-40-30M24030
Sensibilidad,I N(mA)D
Sensibility
OPERATIONMODE.
SELF-RECLOSINGMODE.OPERATION
-Toenabletheautomaticreclosing,theredtransparentlidhastobeclosedslippingsoftly
onRCCB. Theequipmentisinautomaticmode,greenledisinON(blinkinginthecase
thatit’selectedisolationcontrolmode)andthereforeafteronedisconnectionbyearth
leakagetriptheequipmentbeganstheautomaticreclo-sing.
-Todisablethisfunction,theredtransparentlidshouldbeopen.Theequipmentisinmanual
mode,greenledisinOFFandthereforeitdoesn’trecloseautomatically.Inthis
operationmodewecancheckRCCBbymeansofpush-button TEST.
-Withthereclosing theequipmentisin mode.
Afteronedisconnectionbyearthleakagetrip,ittriestorealizeuptoamaximumof6
reconnectionswithatimebetweenreclosuresof10,20,30,60,120y600seconds.In
thissituationtheredledisblinkingslowlyindicatingthetimingbetweenreclousures.
Reachingtonotreclosepermanentifthenumberofreclousureshavebeenfinished
andtheproblemcontinues.InthiscasetheredLEDremainsinONfixedly.The
timetoresetthenumberofreclousuresis300seconds.
-Witchthereclosing ,itrealizesatestofearthleakage.Ifthetestis
negative,theequipmentwillrecloseautomatically.Ifthetestispositive,theequipment
willnotrecloseandthetimewillpass5secondsofsupervisionduringwitchthered
ledblinksfast.Whenthisperiodisfinishedtheequipmentlocks,leavingthe
equipmentastateofnon-permanentreconnection,witchtheredledinONfixely.
Auxiliarypowersupply.....................230/400Vac50-60Hz
Rated.......................................40 A c.a./63 A c.a.
Sensitivity,I n........................30mA
Resistancetoshockwaves.....250 A 8/20 s/200 A 0,5 s
Ratedcutoffpower..................6.000 A segunVDE0664
Ratedopeningandclosing.......................500 A
Class............................................................................ A (IEC1008.1)
Numberofpoles...........................................................2/4
Tension Test...............................................................2polos,entre140y230Vac
4polos,entre190y400Vac
BornesConnection....................................................35mm2
Protectiongrade...........................................................IP40(DIN40050)
TemperatureStock....................................................-55Ca55C
Temperatureservice.....................................................-25Ca55C
Standards.....................................................................IEC61008.1
ColorBox......................................................................RAL 7035
switchdown timesequence
switchupwards
FEATURESOFRCCB
D
m m
InterruptorDiferencial
2/4polos
Frontaldeslizante
parabloqueo/resetequipo
Frontsliderforblockingand
resetequipment
LED-sindicando
estadodelequipo:
.EstadoON
.Estadodisparado
.Estadoreconexion
Conmutadorfrontalpara
seleccionarmodo
reconexion.
GENERALDESCRIPTION
DESCRIPTIONOFLED´sANDSWITCH
-RCCBclass A (IEC1008.1)
-Ithasself-reclosingsystem.
·IsolationControlMode
·T
imeSequenceMode
-MountinginDINrail46277(EN50022)
-GreenLED.
·MANUAL reclosing(OFF)
· AUTOMATICreclosing(ON)
-Blinkingfast,it’sindicatingthereclosingsequence.
-ReclosingMode.
·Supervisionofearthleakage.SwitchupwardsM
·Timesequence.Switchdown. T
-RedLED.
·OFF,RCCBisnottripped.
·ON,RCCBistripped.
-Blinkingslow,it’scountingthereclosingsequence.
-Blinkingfast,thereclosingsequencehasbeenfinished,
butearthleakageisbeingdetected,avoidingthe
reconnectionwhileearthleakageremains.
·Fixed,thereisaearthleakagetripanditisinnotself-reclosing
situation.
LEDsindicating
thestatusofequipment:
.AUT
O/ON
.Trip/Reclosing
RCCB2or4poles
Frontswitchforconfigure
self reclosingtype
-
P26614REC2C2P-63-30M26330
P26612REC2C4P-40-30M44030
P26
615REC2C4P-63-30M46330
ATENCION:Estesistemadereconexionsoloesvalidoparalasproteccionesde2polos.
ATENTION: ThisfunctionisonlyavailableinRCCB2poles.
C
C
C
-DIMENSIONS (mm)
Contactoauxiliar
Auxiliarycontact
M98240201-20-12A
Vista de página 0
1 2

Resumo do Conteúdo

Página 1 - SEL-RECLOSINGRCCB

INTERRUPTORDIFERENCIAL DERECONEXIÓN AUTOMÁTICASEL-RECLOSINGRCCBDESCRIPCIÓNGENERALDESCRIPCIÓNLED´s Y MODOREARME.-InterruptorDiferencialclase

Página 2 - CARGA /LOAD

M98240201-20-12A2NN11NN2MotorReconexionAutomatica230Vac-50HzCARGA /LOAD13mmMAX.16-25mm2.12TTESTOOOFFFNMONTAJEENCARRIL DIN/MOUNTINGINDIN

Comentários a estes Manuais

Sem comentários