Circutor DHB Series Manual do Utilizador Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 54
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
31
Display colour when the displayed value is
higher than in the register 7600 and less than
in register 7601.
4011
CoLbE
w/r 0...2
Value
0 red
1 green
2 orange
Display colour when the displayed value is higher
than in the register 7601
4012
CoLuP
w/r 0...2
Value
0 red
1 green
2 orange
0 RMS voltage
1 RMS current
2 Active power
3 Reactive power
4 Apparent power
5 Active power factor
6 Ratio of reactive/active power
7 Phase shift
8 Frequency
9 Input of active energy
10 Output of active energy
11 Input of reactive energy
12 Output of reactive energy
13 15 minutes’ mean active power
14 10 minutes’ mean voltage
15 10 secondes’ mean frequency
Value
Kind of the input quantity type on which the alarm 1
has to react.
4013
P_A1
w/r 0...15
Vista de página 30